This website contains information intended exclusively for physicians, pharmacists, and other qualified healthcare professionals.

Please confirm your status to continue

By clicking “Yes,” you confirm that you are a licensed healthcare professional and acknowledge that this content is intended for professional use only and not intended for use by the general public.

{"id":2196,"date":"2020-08-27T20:20:33","date_gmt":"2020-08-27T19:20:33","guid":{"rendered":"https:\/\/diagnosticgreen.com\/row\/?page_id=2196"},"modified":"2025-11-07T14:32:34","modified_gmt":"2025-11-07T14:32:34","slug":"frequently-asked-questions-ic-flow-imaging-system","status":"publish","type":"page","link":"https:\/\/diagnosticgreen.com\/row\/frequently-asked-questions\/frequently-asked-questions-ic-flow-imaging-system\/","title":{"rendered":"Frequently Asked Questions – IC-Flow Imaging System"},"content":{"rendered":"\t\t
\n\t\t\t\t\t\t
\n\t\t\t\t\t\t
\n\t\t\t\t\t
\n\t\t\t
\n\t\t\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\t\t\t\t\t

Frequently
Asked Questions<\/h1>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t
\n\t\t\t\t\t\t
\n\t\t\t\t\t
\n\t\t\t
\n\t\t\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\t\t\t\t\t

Frequently Asked Questions
IC-Flow Imaging System<\/h2>

We\u2019ve put together some commonly asked questions about IC-Flow Imaging System and it’s use with Indocyanine Green, ICG
in Fluorescence Guided Surgery
If you can\u2019t find the answer to your question please contact us<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t

\n\t\t\t\t
\n\t\t\t\t\t\t\t
\n\t\t\t\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t
\n\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\tWhat is the IC-Flow\u2122 Imaging System?<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t

IC-Flow\u2122 Imaging System, is Diagnostic Green\u2019s CE approved imaging camera. It is a small, compact and easy to use handheld device used to visualise and record tissue fluorescence.
The IC-Flow\u2122 Imaging System is a medical infrared camera for viewing fluorescent images of ICG dye in the patient\u2019s body.
<\/span><\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t

\n\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\tHas the IC-Flow\u2122 Imaging System CE Mark?<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t

Yes, in March 2016 the IC-Flow\u2122 Imaging System received its CE mark approval as a Medical Device Class I.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t

\n\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\tWhat is the intended use of the IC-Flow\u2122 Imaging System?<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t

The intended use is as an imaging system, used in capturing and viewing fluorescent images for the visual assessment of blood flow as an adjunctive method for the evaluation of tissue perfusion, and related tissue-transfer circulation in tissue and free flaps used in plastic, micro-reconstructive surgery, and organ transplant procedures.<\/p>

The device is used by surgeons or trained health care professionals within a doctor\u2019s office environment and in hospital settings.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t

\n\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\tHow does the IC-Flow\u2122 Imaging System operate?<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t

The IC-Flow\u2122 Imaging System provides for the visualisation of the distribution and intensity of a fluorescent dye, Indocyanine Green (Verdye, ICG) in human tissue.<\/p>

Indocyanine Green, ICG is reconstituted and injected. Through the use of the IC-Flow\u2122 Imaging System, a near-infrared light is exhibited. The LED light source excites the Indocyanine Green, ICG molecules in the tissue and the Indocyanine Green ICG emits fluorescence.<\/p>

The fluorescent light of ICG is detected by the camera filters and images or videos are displayed on a monitor and\/or touch screen.<\/p>

\"ICG<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t

\n\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\tWhere can I find a technical sheet for the IC-Flow\u2122 Imaging System?<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t

The technical specifications are included in the table below and further information is available in the IC-Flow\u2122 Imaging System brochure, if you would like to download the full brochure at our Resources Page Resources Pagee<\/a><\/p>
Images\/ Display<\/td>Display of fluorescence image on monitor and touchscreen<\/td><\/tr>
Internal memory<\/td>Internal memory of 800 MB
(100 min videos\/ 1000 images)
Transfer to USB stick<\/td><\/tr>
Video format<\/td>MPEG1<\/td><\/tr>
Picture format<\/td>JPEG<\/td><\/tr>
Field size of view<\/td>640 x 480 pixel<\/td><\/tr>
Focus\/ zoom
Work distance<\/td>
Manual\/No
Approx. 15-20 cm<\/td><\/tr>
Light source<\/td>LED<\/td><\/tr>
Functions<\/td>Video & image recording
Data transfer to USB stick<\/td><\/tr><\/tbody><\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t
\n\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t<\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\tHow easy is the IC-Flow\u2122 Imaging System to set up and use?<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t

The IC-Flow\u2122 Imaging System is very easy and uncomplicated to set up.
Simply follow the instructions below and within a few minutes the imaging system will be ready to use.<\/p>